Skip to main content

Technical Specifications of Harley PWL4100S 1310nm Optical Transmitter

The PWL4100S from Harri is part of the PWRLink II series of 1310nm DFB laser transmitter modules. The PWRLink II transmitter is designed for advanced broadband networks, capable of functioning independently in local distribution networks or working in conjunction with Harri's external modulation optical transmitter series to form a complete fiber optic transmission network.
Application

Hybrid Transmission of Broadcasting Television and Digital Broadcasting

DFB 1550nm hybrid cascade can be used for trunk, ultra-trunk, and interconnection transmission.

A high-quality signal transmission with a bandwidth of 1000MHz can reach a distance of up to 45km.

Analog and Digital Broadcasting

CNR and Fiber Loss Relationship Table (80 NTSC Channels Note 1, 2, 3)

Model Description

PWL 41xxS-zz

xx = model number (02 to 15)

zz = Connector Type (AS, AF, US, UF, AE)

Link Performance
 
Carrier-to-Noise Ratio (CNR)
Please refer to the image above.

C/CSO Note 4
>65dB

C/CSTB Note 4
>71dB
When the optical link loss includes splitter loss, a corresponding increase of 0.1dB in CNR is required for every 1dB of splitter loss.

Optical Output Characteristics
 
Working wavelength
1300 to 1320 nm

Model
Optical Power (dBm)

PWL 4102S
PWL 4103S
PWL 4104S
PWL 4105S
PWL 4106S
PWL 4107S
PWL 4108S
PWL 4109S
PWL 4110S
PWL 4111S
PWL 4112S
PWL 4113S
PWL 4114S
PWL 4115S
2.5±0.5
3.5±0.5
4.5±0.5
5.5±0.5
6.5±0.5
7.5±0.5
8.5±0.5
9.5±0.5
10.5±0.5
11.5±0.5
12.5±0.5
13.5±0.5
14.5±0.5
15.5±0.5 

RF Input
Input Level Range
15 to 22 dBmV

Working bandwidth
45 to 1003 MHz

Frequency Response
<1dB (Peak-to-Valley Value)

RF level adjustment range
10dB

Impedance
75Ω

Return Loss
>16dB

Level Control
Manual (MGC) / Automatic (AGC)

User Interface
Front Panel
Dual-state indicator LED
Normal = Green, Alarm = Red
Module Selection Indicator
Yellow LED
RF Attenuation Adjustment
 
Monitoring Port
Laser RF Drive Monitoring

Flatness
±0.5dB

Reflection Loss
>16dB

Connector Type
Standard Yin Type F

NETWatch Element Management System
NET Interface
RS-485 Interface (on HLP4200)

Carrier
External Generation

Power Requirements
 
Rated value
+24VDC, HLP4200 platform bus power supply

Maximum Value
+28VDC

Power Consumption
22W (maximum)

Environmental Requirements
 
Operating temperature range Note 5
-20 to +65 degrees Celsius

Storage temperature range
-40 to +70 degrees Celsius

Automatic three-speed fan adjustment
40 degrees Celsius and 50 degrees Celsius

Relative Humidity
0-85% non-condensing

Laser Overheat Protection
Software and Hardware Control
Structural Parameters

Volume: Width × Height × Length
3.3cm × 11.2cm × 32.2cm

Weight
0.95kg

Installation
Insert HLP4200 platform through HMC4001.

Fiber Connector Types
SC/APC Note 6

Types of RF Connectors
Standard F-type, RG-59 coaxial cable (diameter approximately 0.64 to 0.8mm)

Comment
Note 1: Unmodulated signals specific to 80 channels in NTSC format, plus a 200MHz wide digital signal at 10dB lower.
Note 2: The optical link refers to the PWL4100S transmitter + 100% fiber + HRM3811 receiver.
Note 3: When a 6dB lower digital signal with a bandwidth of 200MHz is added, the typical CNR value decreases by 0.5dB.
Note 4: This parameter represents typical values for an all-fiber link. Worst-case values: CSO reduced by 1dB, CTB reduced by 2dB.
Note 5: Throughout the entire operating temperature range, the CSO and CTB indicators will vary by 2 dB.
Note 6: SC/APC is the connector type recommended by Harley. Users may specify other types of connectors.